-----BEGIN PGP SIGNED MESSAGE-----
Hash: SHA1

hello Lizhe--

> 
> I am using X-plor to refine a protein structure, and now I have some
> questions: 
> 
> 1) The protein structure and its corresponding X-ray structure have
> four copies in one unit cell.  So which way is better?  A: First build
> up the unit cell containing four copies of the protein, then run MD
> under periodic boundary condition (PBC) by Xplor-NIH.  B: Start with
> one protein copy, then define unit cell and the four symmetric
> operations by Xrefin, then run MD under periodic boundary condition
> (PBC) by Xplor-NIH.

I am not an expert on crystal refinement, but I believe you want to use
some sort of NCS restraint for this
http://nmr.cit.nih.gov/xplor-nih/doc/current/xplor/node339.html

The strict ncs restraint will allow you to have only a single copy of
the structure.

> 
> 2)    How can I set up a real periodic boundary condition by Xplor-NIH, (by 
> which command)? 
> 

Please check out the examples in tutorial/xtalrefine

If you wish to use the Python interface, I do have an example, but it's
for a system with only one protein copy per unit cell.

best regards--
Charles
-----BEGIN PGP SIGNATURE-----
Version: GnuPG v1.4.9 (GNU/Linux)
Comment: Processed by Mailcrypt 3.5.8+ <http://mailcrypt.sourceforge.net/>

iEYEARECAAYFAkpnepoACgkQPK2zrJwS/lanUgCfQ1rE3L6v6EduIcUSKNyLva2+
fGsAn3AkBm3PYBXaxr0aKEQhhr7pq/Cr
=aSgC
-----END PGP SIGNATURE-----

Reply via email to