Hello Simon--
>
> At present I have generated pdb, psf and par for PRE docking using spin
> labels in 6 positions with four orientations for each. I have recently
> attempted to utilise the same script for generation of the above files
> for 9 spin labels. However, when I do so I am presented with a
> parameter error, such that it cannot find a specific atom of 7th spin
> label and therefore xplor terminates. I have not encountered this error
> before using 6 positions and all I have done is to increase the total
> number of spin labels and included the relevant mutation sites for xplor
> to read. Is it possible that xplor cannot handle too many i.e. > 24
> spin labelled positions due to the number of coordinates being read in
> and created at one time? I have further tried using 7 spin labels and I
> am presented with the same error.
>
Please send the error output, and we should get to the bottom of this
issue quickly. I modified eginput/pre/refine/generate.py in the
Xplor-NIH distribution to generate 9 tags, and that worked just fine.
best regards--
Charles
-------------- next part --------------
--
Charles Schwieters email: Charles at Schwieters.org
www: http://schwieters.org/cds
phone: (301) 402-4914 PGP key: http://schwieters.org/cds/pgp.txt
-------------- next part --------------
A non-text attachment was scrubbed...
Name: not available
Type: application/pgp-signature
Size: 198 bytes
Desc: not available
Url :
http://dcb.cit.nih.gov/pipermail/xplor-nih/attachments/20120302/6745021d/attachment.bin