Hi,

Our lab recently switched from XPLOR-NIH version 2.19 to version 2.33.  It
would seem that the former proton stereospecificity (HD** or HG**) in the
NOE restraint files have changed to only accept HD(1 or 2)* or HG(1 or 2)*.
 My methyl protons aren't stereospecifically assigned and I was wondering
how XPLOR is treating those proton and how we keep the ambiguity?  Do we
have to use the potential described in:

Kuszewski, J., Gronenborn, A.M. & Clore, G.M. (1996) A potential
involving multiple proton chemical shift restraints for
non-stereospecifically assigned methyl and methylene protons. J. Magn.
Reson. Series B 112, 79-81


Thanks


-- 
Marie-Laurence Tremblay, PhD candidate
Department of Biochemistry and Molecular Biology
Dalhousie University
5850 College St.
Halifax NS, Canada
B3H 1X5
mltremblay at dal.ca
Phone:902-494-4812