Hello Charles,

Thanks for the clarification. But I am confused from the 7 pseudo atoms.

>From the example gb1_rdc [from the tutorial]. I see that model.pdb has
ATOM    856  X   ANI   500     322.383 -47.025 154.522  1.00  3.06
ATOM    857  Y   ANI   500     322.080 -50.957 156.088  1.00  4.37
ATOM    858  Z   ANI   500     323.128 -50.368 152.019  1.00  4.35
ATOM    859  OO  ANI   500     324.205 -49.405 154.647  1.00  4.04

These 4 should define the tensor axis. And the RDC definition is done :
assign ( resid 500  and name OO  )
       ( resid 500  and name Z   )
       ( resid 500  and name X   )
       ( resid 500  and name Y   )
       ( resid 2    and name N   )
       ( resid 2    and name HN  )  -3.7330  0.2000

Out of which the first 4 lines are the axes and the remaning 2 are the
actual atoms.
Am I wrong ? And about the perpendicularity :
Do you mean that I need not manually maintain perpendicularity in the
model.pdb?

Sorry if I am overlooking something.
Thanks
Santhosh


On Sat, May 11, 2013 at 11:16 AM, Charles Schwieters <charles at schwieters.org
> wrote:

>
> Hello Santhosh--
>
> >
> > In refinement of structures using RDC's, we use 4 pseudo-atoms to define
> an
> > axis and these are part of the PDB also. For more than one RDC dataset,
> we
> > should have more than such 4 pseudo-atoms. Now the questions are :
>
> If you use the Python interface (suggested) then there are 7 pseudo
> atoms per alignment tensor.
>
> >
> > 1). Should the four atoms be created as a axis? I mean should O-XX be
> > perpendicular to O-YY and so on? Or could it be any four atoms far away
> from
> > the protein? In the examples, they are mostly perpendicular.
>
> The axes must be perpendicular, or you will get nonphysical
> results. In a proper Xplor-NIH Python script, you don't have to
> manually configure any pseudo atoms, and the axes will remain
> perpendicular irrespective of force constants.
>
> >
> > 2). In case of multiple RDC constraints, would there be a problem if I
> > overlap many such pseudo-atoms on top of each other?
>
> No- overlap of pseudo atoms corresponding to different alignment
> tensors is no problem, and with standard parameters there should be no
> VDW energy calculated.
>
> best regards--
> Charles
>
> --
> Charles Schwieters     email:   Charles at Schwieters.org
>                        www:     http://schwieters.org/cds
> phone: (301) 402-4914  PGP key: http://schwieters.org/cds/pgp.txt
>
>
>
-------------- next part --------------
An HTML attachment was scrubbed...
URL: 
<http://dcb.cit.nih.gov/pipermail/xplor-nih/attachments/20130511/da52cc95/attachment.html>

Reply via email to