Hello Xplor community:
I'm using the anneal.py script and I'm having trouble changing the threshold for ANGL and IMPR. This is a fragment of the script that I am using.

potList.append( XplorPot("BOND") )
potList.append( XplorPot("ANGL") )
potList['ANGL'].setThreshold( 5 )
rampedParams.append( MultRamp(0.4,1,"potList['ANGL'].setScale(VALUE)") )
potList.append( XplorPot("IMPR") )
potList['IMPR'].setThreshold( 5 )
rampedParams.append( MultRamp(0.1,1,"potList['IMPR'].setScale(VALUE)") )

The output file says that there are violations greater than 2, which shows that the threshold was not changed to 5 as I expected. I also changed it in the xplorPotTools.py and the result was exactly the same.

(atom-i |atom-j |atom-k ) angle equil. delta energy const.

( 9 N1 | 9 CA1 | 9 CD1 ) 105.853 103.000 2.853 1.240 500.000 ( 9 N1 | 9 CA1 | 9 CD2 ) 105.851 103.000 2.851 1.238 500.000 ( 9 N1 | 9 CA1 | 9 CA2 ) 105.853 103.000 2.853 1.240 500.000 ( 9 CD1 | 9 CA1 | 9 CD2 ) 112.835 109.500 3.335 1.694 500.000 ( 9 CD1 | 9 CA1 | 9 CA2 ) 112.834 109.500 3.334 1.693 500.000 ( 9 CD2 | 9 CA1 | 9 CA2 ) 112.835 109.500 3.335 1.694 500.000
 Number of violations greater    2.000:     6
 RMS deviation=   0.483
.
.
.
.
.
(violations:  bond: 0  angle: 6  improper: 10)

Regards,
      Celia González
_______________________________________________
Xplor-nih mailing list
[email protected]
https://dcb.cit.nih.gov/mailman/listinfo/xplor-nih

Reply via email to