Hi Mark--

> 
> I tried both approaches (1) wrefine_Zn.py & (2) wrefine_Zn_cs.py
> (below), but both give what might be the same error (with the errors
> at the bottom) 

>  %CODBON-ERR: missing bond parameters %%%%%%%%%%%%%%%%%%%%%%%%%%
>   bond energy constant missing.
>   target bond length missing.
>   ATOM1: SEGId="    ",  RESId="401 ",  NAME="ZN+2",  CHEMical="ZN+2"
>   ATOM2: SEGId="    ",  RESId="6   ",  NAME="SG  ",  CHEMical="SH1E"

Sorry- the zinc finger parameter file works with the default Xplor-NIH
parameters. For water refinement, different chemical types are
required. Please take the attached file and place it in your
calculation directory.


########################################################################

To unsubscribe from the XPLOR-NIH list, click the following link:
http://list.nih.gov/cgi-bin/wa.exe?SUBED1=XPLOR-NIH&A=1

Attachment: zn-finger-allhdg5.3.par
Description: Binary data

Then, replace the line

protocol.initParams('extra/zn-finger.par')

with

protocol.initParams('zn-finger-allhdg5.3.par')

I have not tested this- please let me know of you have difficulties.

Charles

########################################################################

To unsubscribe from the XPLOR-NIH list, click the following link:
http://list.nih.gov/cgi-bin/wa.exe?SUBED1=XPLOR-NIH&A=1

Reply via email to