Hello, and happy new year all. I compiled the last SVN and I see three bugs in the QT interface. Am I the only one to get this behaviour?
After loading/re-loading different xmls, and playing/pausing, I get one or both of those : 1- The main 3D view displays nothing, or just the boxes (in a triaxial test). Opening a new view fixes the problem *sometimes* (i.e. the new view shows balls while the main one still doesn't). Re-starting Yade fixes the problem for most cases, but for a TriaxialTestWater, I need to restart Yade AND open a secondary view before I see anything. 2- The good old timestep bug (or is brother) is back : reloading the simulation switch the time-step from "auto" to "fixed", and let the sample explode... In all cases : 3- Closing Yade needs many mouse clicks (close controller first, then close the small Yade window). ctrl+C in the terminal won't work (with python interface), and even worst, typing "quit" results in this, and then the terminal is stuck : /"In [1]: exit Out[1]: Type exit() to exit. In [2]: quit Out[2]: Type quit() to exit. In [3]: quit() Do you really want to exit ([y]/n)? y Bye."/ Thank you. Bruno -- _______________ Chareyre Bruno Maitre de conference Grenoble INP Laboratoire 3SR - bureau E145 BP 53 - 38041, Grenoble cedex 9 - France Tél : 33 4 56 52 86 21 Fax : 33 4 76 82 70 43 ________________ _______________________________________________ Mailing list: https://launchpad.net/~yade-dev Post to : [email protected] Unsubscribe : https://launchpad.net/~yade-dev More help : https://help.launchpad.net/ListHelp _______________________________________________ yade-dev mailing list [email protected] https://lists.berlios.de/mailman/listinfo/yade-dev