> looking at the formula in line 190 of PeriIsoCompressor, it does not look
> dimensionally correct either. Can anyone correct me if I am wrong?

190 is correct, see the equations in the comment. It is a bit the same
thing as with boxes in triaxial test. The only problem is the way
stiffness is defined in periodic cell doesn't apply for CundallStrack
laws, that is why I implemented dynamic boundaries originaly.

 Does it
> matter, at this point, if the strain rate is updatd in such a way that the
> additional term is dimensionally incorrect?

It doesn't matter as long as you can get a stable packing with the
desired internal stress.

Regards.

Bruno