Question #147640 on Yade changed: https://answers.launchpad.net/yade/+question/147640
Chareyre proposed the following answer: Hi, If the capillary stress and output succion are null, it is because either the input succion (capillaryPressure) is too high (liquid bonds are all broken) or too low (the sample is almost saturated). With the particles sizes we have in the default example, it needs a very low succion to get meniscii. I just tried with 100Pa, it works. It also means you get a very small capillary stress (~1Pa!) and negligeable effect on stress-strain behaviour. Although it is physicaly correct with spheres diameters of 5cm, it is probably not what you want. So, yes, you should generate smaller grains. ... and I'll change the default size eventually... Bruno -- You received this question notification because you are a member of yade-users, which is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : [email protected] Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp