New question #168152 on Yade: https://answers.launchpad.net/yade/+question/168152
Hello, I am just wondering if we can use the stress control instead of strain control in the triaxial test since I am trying to simulate the repeated load triaxial test. In that test, the sample will be loaded at 12 KPa for 1 second and then unload for 0.3 second. That loading condition keeps going for 1000 cycles. Many thanks, Bao -- You received this question notification because you are a member of yade-users, which is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : [email protected] Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp