Question #295035 on Yade changed: https://answers.launchpad.net/yade/+question/295035
Jérôme Duriez proposed the following answer: For compressive situations at the contact scale, the unp numeric value will stay the same as long as you do not change it a second time. In particular, unp will stay equal to your initial penetrationDepth: the initial overlap. Obviously, the penetrationDepth variable itself is free to change during the simulation (because it needs to be, and is, updated every time step), but this will not reflect into unp... unp might evolve without any user's action in situations related to tensile regime only (provided your simulation allows tensile loadings at the contact scale, and you're using fragile = false) -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : [email protected] Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp