Question #626580 on Yade changed:
https://answers.launchpad.net/yade/+question/626580

Bruno Chareyre posted a new comment:
Just a note: if you set the permeabilityFactor negative then the value is used 
as a Darcy conductivity (probably not a perfect equality but very similar order 
of magnitude). It implies that in this case conductivity becomes independent of 
particle sizes and of fluid viscosity. 
It can help if you want to use particle size just as a discretization parameter.
B

-- 