Question #626580 on Yade changed: https://answers.launchpad.net/yade/+question/626580
Bruno Chareyre posted a new comment: Just a note: if you set the permeabilityFactor negative then the value is used as a Darcy conductivity (probably not a perfect equality but very similar order of magnitude). It implies that in this case conductivity becomes independent of particle sizes and of fluid viscosity. It can help if you want to use particle size just as a discretization parameter. B -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : yade-users@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp