Bruno Chareyre proposed the following answer:
An alternative approach, which may fit your needs or not, would be to use 
TriaxialStressController by prescribing a very small confinement on the other 
two directions. That would prevent particles from flying away and it would keep 
the boundaries in contact with the specimen, which makes defining transverse 
strain straightforward.
If the confinement is small enough it should approach the uniaxial response. 