Question #688652 on Yade changed:
https://answers.launchpad.net/yade/+question/688652

    Status: Needs information => Solved

Mumić confirmed that the question is solved:
Hello again and thanks for the reply.

>set epsCrackOnset and sigmaT to arbitrary large values (like 1e99)

I ran some simulations using 1e99 and looks like this solved the problem, now 
Macro Poisson is varying with the Micro value.
Low kT/kN values are now behaving like expected based on Šmilauer's thesis 
(e.g. kT/kN=0 ⇒ v≃0.259)

Thank you for the support, I'll continue now towards the inelastic part
of the calibration.

Best regards!

-- 