Question #688652 on Yade changed:
https://answers.launchpad.net/yade/+question/688652
Status: Needs information => Solved
Mumić confirmed that the question is solved:
Hello again and thanks for the reply.
>set epsCrackOnset and sigmaT to arbitrary large values (like 1e99)
I ran some simulations using 1e99 and looks like this solved the problem, now
Macro Poisson is varying with the Micro value.
Low kT/kN values are now behaving like expected based on Šmilauer's thesis
(e.g. kT/kN=0 ⇒ v≃0.259)
Thank you for the support, I'll continue now towards the inelastic part
of the calibration.
Best regards!
--