Question #690803 on Yade changed:
https://answers.launchpad.net/yade/+question/690803
Status: Open => Answered
Bruno Chareyre proposed the following answer:
Hi,
> should I set bndCondIsPressure as [0,0,0,0,0,0] when there is no flux?
Yes.
> And as [0,0,1,0,0,0] when there is flux along the y axis? Or
[0,0,1,1,0,0]?
For a permeameter you would surely impose pressure with [0,0,1,1,0,0], but not
everything is permeameter, so...
I don't know. "there is flux" is not a boundary condition. :)
If you want to impose pressure on one boundary then you turn that one as
"isPressure".
Regards
Bruno
--
You received this question notification because your team yade-users is
an answer contact for Yade.
_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to : [email protected]
Unsubscribe : https://launchpad.net/~yade-users
More help : https://help.launchpad.net/ListHelp