Question #691610 on Yade changed:
https://answers.launchpad.net/yade/+question/691610
Status: Answered => Open
Leonard is still having a problem:
Hi Jan,
Do you use the same particle sizes as the references?
>>No, the particle size of the paper I mentioned is larger than mine. (size of
>>sample: 90*90*180 mm, number of particles 1000).
So I guess this is the reason that they have larger ForceN.
2*a*a = (2*a*a*a) ^ (2/3) * 2^(1/3)
>> Why use this formula to transfer from per volume to per area ? Sorry I am
>> slow about this :(
Thanks again!
Leonard
--