Question #691610 on Yade changed:
https://answers.launchpad.net/yade/+question/691610

    Status: Answered => Open

Leonard is still having a problem:
Hi Jan,

Do you use the same particle sizes as the references?
>>No, the particle size of the paper I mentioned is larger than mine. (size of 
>>sample: 90*90*180 mm, number of particles 1000).
So I guess this is the reason that they have larger ForceN.

2*a*a = (2*a*a*a) ^ (2/3) * 2^(1/3)
>> Why use this formula to transfer from per volume to per area ? Sorry I am 
>> slow about this :(

Thanks again!

Leonard

-- 
You received this question notification because your team yade-users is
an answer contact for Yade.

_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~yade-users
More help   : https://help.launchpad.net/ListHelp

Reply via email to