New question #692799 on Yade:
https://answers.launchpad.net/yade/+question/692799

Hi,

When I carry out the triaxial compression simulation, I found that I run the 
exact same simulation twice but could gain different shear response, i.e., 
loading the same sample.yade.gz, and using the same script for deviatoric 
loading, but the stress-strain curve and volumetric response is not exactly 
same, see one example at [1] if you are interested.

I'd like to say that the results of the two are basicly agree very well, the 
only different just occurs at very large strains.  I am  strict about this 
because I wonder if there are anything wrong that I am not aware, or it is just 
some numerical random issues?

Thanks

Leonard