New question #698594 on Yade:
https://answers.launchpad.net/yade/+question/698594

Hi,
I carried out triaxial compression tests at two boundary conditions (one case 
with rigid wall and one case with periodic boundary), the two cases use the 
same material, the same particle size distribution and paticle number, same 
contact law and the same initial void ratio, at same confining pressure, same 
strain rate (I think), and almost the same of sample size. But I got really 
different mechanical response, especially for the volumetric behaviour, the 
periodic one shows contractive behaviour, while the rigid case shows dilative 
behaviour. I thoungh I have controlled all the conditions (except boundary 
condition) the same. 
It is not surprise that there are some difference, but is it normal to have 
such a big difference?  Or did I miss some factors which can also lead to the 
difference?

Thanks!
Leonard

-- 
You received this question notification because your team yade-users is
an answer contact for Yade.

_______________________________________________
Mailing list: https://launchpad.net/~yade-users
Post to     : [email protected]
Unsubscribe : https://launchpad.net/~yade-users
More help   : https://help.launchpad.net/ListHelp

Reply via email to