Question #698778 on Yade changed: https://answers.launchpad.net/yade/+question/698778
Zoheir Khademian posted a new comment: Thanks so much Robert. After checking the VTK output for pressure, I noticed the cell I was injecting to was not registered as a cavity. So, simply applying the flux to one of the cavity cells in the cavity list solved the problem. Now, the influx and outflux are the same. One more question though: In your flux calculation above, the unit of q the flux seams to be m/s. Do we need to have the area of the cavity boundary to obtain the flux in m3/s? if so, what is the easiest way to get that area? Thanks again for the help! -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : [email protected] Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp