Question #700761 on Yade changed: https://answers.launchpad.net/yade/+question/700761
Status: Open => Answered Robert Caulk proposed the following answer: Hello, Please do not ask 4 separate questions in one thread. Please read our forum guidelines [1]. >but I found that these two values remained constant throughout the process (about - 1.02 and 1.02 in my simulation).It puzzles me. Well ya, you are setting the permeability constant. Please review the command you are using for permeability [2]. >2. I also want to know what is the unit of the value measured by flow.getBoundaryFlux.(I checked the help document of Yade and couldn't find the relevant results) Yade is generally unit-less. You decide the units based on your input parameters. Yade is just a calculator. Generally it is recommended to stick to SI input units so that your results are in SI units. i.e. this flux would be m^3/s in SI units. >By the way,is this function(flow.getBoundaryFlux) used to measure permeability in flowengine. I dont quite understand, that is the function used to measure fluid fluxes. You need fluid fluxes to compute permeability. Cheers, Robert [1]https://www.yade-dem.org/wiki/Howtoask [2]https://yade-dem.org/doc/yade.wrapper.html#yade.wrapper.FlowEngine.permeabilityFactor -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : yade-users@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp