New question #701228 on Yade: https://answers.launchpad.net/yade/+question/701228
Hi, I am measuring pore radius and pore volume using the TwoPhaseFlowEngine() for my packing of sphere (using ymport), I am getting following error message when I run my code: "negative volume for an ordinary pore (temp warning, should still be safe)" *** stack smashing detected ***: terminated, than Aborted (core dumped), and the whole thing crashes. Best regards, Mithu Here is my code: import os import numpy as np import pandas as pd from yade import pack, ymport from yade import utils, plot, timing O=Omega() path_data='/home/mithushan/Swelling/PH101_20_1mm_removed_die/Particle_pos' filename='PH101_particle_pos_20_1_2.0000009999999997.txt' a=ymport.text(os.path.join(path_data,filename), shift=Vector3(0, 0, 0), scale=1.0) O.bodies.append(a) unsat = TwoPhaseFlowEngine() unsat.initialization() unsat.getCellVoidVolume(100) unsat.getCellInSphereRadius(100) unsat.savePoreNetwork() -- You received this question notification because your team yade-users is an answer contact for Yade. _______________________________________________ Mailing list: https://launchpad.net/~yade-users Post to : yade-users@lists.launchpad.net Unsubscribe : https://launchpad.net/~yade-users More help : https://help.launchpad.net/ListHelp