Reviewed: https://review.openstack.org/561186 Committed: https://git.openstack.org/cgit/openstack/neutron/commit/?id=806d96cbbe45fcd473935e777a2a56037fbb9d12 Submitter: Zuul Branch: master
commit 806d96cbbe45fcd473935e777a2a56037fbb9d12 Author: Sławek Kapłoński <[email protected]> Date: Fri Apr 13 11:34:42 2018 +0200 Override ovsdb_timeout default value in ovs_cleanup tool In case when there is a lot of ports to clean in bridge, default ovsdb_timeout which is set for 10 seconds is not enough. This patch overrides default 10 seconds timeout in neutron-ovs-cleanup tool to 600 seconds. 600 seconds value was tested experimentally on my dev environment for at least 10000 ports in bridge. In case when user will have more ports to delete with this script, it will be required to increase this ovsdb_timeout value in configuration. Change-Id: I79a554acdb1d6d61903be0c42d0215d302884e93 Closes-Bug: #1763604 ** Changed in: neutron Status: In Progress => Fix Released -- You received this bug notification because you are a member of Yahoo! Engineering Team, which is subscribed to neutron. https://bugs.launchpad.net/bugs/1763604 Title: neutron-ovs-cleanup failing when there are too many ports in bridge Status in neutron: Fix Released Bug description: Patch https://review.openstack.org/#/c/536000/ improved a lot performance of neutron-ovs-cleanup utility but still if there is big number of ports in one bridge (e.g. 5000) neutron-ovs-cleanup utility might fails because of ovs connection timeout. To manage notifications about this bug go to: https://bugs.launchpad.net/neutron/+bug/1763604/+subscriptions -- Mailing list: https://launchpad.net/~yahoo-eng-team Post to : [email protected] Unsubscribe : https://launchpad.net/~yahoo-eng-team More help : https://help.launchpad.net/ListHelp