After digging into the implementation again, I noticed [DEFAULT]
report_interval is actually used to determine interval between metering
report, instead of agent status report.
** Changed in: neutron
Assignee: Takashi Kajinami (kajinamit) => (unassigned)
** Changed in: neutron
Status: In Progress => Invalid
--
You received this bug notification because you are a member of Yahoo!
Engineering Team, which is subscribed to neutron.
https://bugs.launchpad.net/bugs/1968468
Title:
metering-agent: Duplicate report_interval parameters
Status in neutron:
Invalid
Bug description:
The neutron-metering-agent service has the following two
report_interval parameters, and these two looks duplicate.
(1)
[DEFAULT]
report_interval=300
(2)
[AGENT]
report_interval=30
Looking at the implementation, (1) is used in configuration.report_interval
in agent status while (2) determines the actual interval in agent side.
Considering consistency with the other agents, we should use (2) only and
deprecate (1).