>>> On 1/30/2009 at  6:22 AM, in message <[email protected]>, Stefan
Hundhammer <[email protected]> wrote: 
> On Dienstag, 27. Januar 2009, Roberto Angelino wrote:
>>     My customer has setup an autoyast installation (sles10 sp1) and it
>> works great.  The problem is log messages are output to the physical
>> console AND over SOL (Serial Over LAN).  This SOL connection is 9600 baud
>> (please don't ask me to tell them to increase--they can't) so the
>> installation can take quite a while because of all the text yast is spewing
>> over this 9600 connection can take some time.  They are asking if there's a
>> way to reduce it or eliminate it?
> 
> Thinking that through once more, why not simply use a ssh installation if 
> LAN 
> is available? Serial over LAN at 9600 baud strikes me as a very odd 
> solution.

LAN install is not an option.  This is a product that uses SLES.  The SOL 
connection
is needed because it connects to a management node and all nodes are controlled
by the management node.  

-robert



--