>>> On 1/30/2009 at 6:22 AM, in message <[email protected]>, Stefan Hundhammer <[email protected]> wrote: > On Dienstag, 27. Januar 2009, Roberto Angelino wrote: >> My customer has setup an autoyast installation (sles10 sp1) and it >> works great. The problem is log messages are output to the physical >> console AND over SOL (Serial Over LAN). This SOL connection is 9600 baud >> (please don't ask me to tell them to increase--they can't) so the >> installation can take quite a while because of all the text yast is spewing >> over this 9600 connection can take some time. They are asking if there's a >> way to reduce it or eliminate it? > > Thinking that through once more, why not simply use a ssh installation if > LAN > is available? Serial over LAN at 9600 baud strikes me as a very odd > solution.
LAN install is not an option. This is a product that uses SLES. The SOL connection is needed because it connects to a management node and all nodes are controlled by the management node. -robert -- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]