Hey Sven,
I made changes to fix this behavior. If you suspect this isn't working,
please let me know.
-Eric
Schuran, Sven wrote:
Hi,
but I am not sure it is working, cause of
##############
Hi,
I don't get it.
Yesterday I had to update my gateway. It reboots.
All Systems behind it got red, and there are although several red ping
events for them.
These events have eventstat==0.
Is here something wrong?
Some devices are connected directly to the gateway and some via a VPN
link.
Sven
##################
Sven
________________________________
Von: John Neiberger [mailto:[EMAIL PROTECTED]
Gesendet: Dienstag, 25. Juli 2006 17:33
An: General discussion of using zenoss system
Betreff: Re: [zenoss-users] Event Suppression
That's very cool. Orion NPM does not do that.
On 7/25/06, Erik A. Dahl <[EMAIL PROTECTED]> wrote:
On Jul 25, 2006, at 11:05 AM, John Neiberger wrote:
>
> How does Zenoss learn the routing topology? That's something
that
> Orion doesn't do, and that makes me even more interested in
Zenoss.
Zenoss builds a model of the layer-3 topology by collecting the
route
tables of all devices when a device is added or auto-discovered.
From this it can build the route tree from the zenping monitor
box
to every box on the net.
-EAD
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users