Hi David,

You want zProdStateThreshold.
1000: no discovery
500: Production
400: Above and Pre-Production
300: Above and Test
0: Above and Maintenance
-1: Above and Decommissioned

-Eric



David Carmean wrote:
I should have been more explicit yesterday but was tired from a long day; that's exactly what I was trying to do and even at Pre-Production the discovery is skipped. That's what surprised me.


On Fri, Feb 09, 2007 at 06:45:12AM -0800, Kristopher D. Dick wrote:

When you add the device, set its Production State drop down to
Pre-Production.

_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users


_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to