Hi David,
You want zProdStateThreshold.
1000: no discovery
500: Production
400: Above and Pre-Production
300: Above and Test
0: Above and Maintenance
-1: Above and Decommissioned
-Eric
David Carmean wrote:
I should have been more explicit yesterday but was tired from a
long day; that's exactly what I was trying to do and even at
Pre-Production the discovery is skipped. That's what surprised
me.
On Fri, Feb 09, 2007 at 06:45:12AM -0800, Kristopher D. Dick wrote:
When you add the device, set its Production State drop down to
Pre-Production.