I use a external temperature sensor but the setup should be similar.

1. Use snmpwalk to find the correct OID
2. Create a data source for that OID
3. Create a data point for the data source
4. Create a graph with both data sources.
5. Setup Thresholds for the data sources
6. Setup a alert rule that uses the thresholds.

You will end up with a cpu temp graph with two lines one for each processor and 
the ability to send a e-mail alert with a threshold is met.