I've upgraded my Zenoss test system to 2.0.5 installing from source.  I am 
still running into the problem of the zeneventlog stopping after about 10 
minutes.

See this (http://community.zenoss.com/forums/viewtopic.php?t=3052) thread for 
further information.

What else can I do to help isolate this problem?



Code:
2007-09-07 15:24:17 INFO zen.zeneventlog: Setting configCycleInterval to 360
2007-09-07 15:24:17 INFO zen.zeneventlog: Setting eventlogCycleInterval to 60
2007-09-07 15:24:21 INFO zen.zeneventlog: wmi prob on SERVER1 skipping
2007-09-07 15:32:25 INFO zen.zeneventlog: wmi prob on SERVER2 skipping
2007-09-07 15:32:26 INFO zen.zeneventlog: wmi prob on SERVER3 skipping
2007-09-07 15:32:26 INFO zen.zeneventlog: Async config notification
2007-09-07 15:32:26 INFO zen.zeneventlog: Async config notification
2007-09-07 15:32:26 INFO zen.zeneventlog: Async config notification
2007-09-07 15:32:26 INFO zen.zeneventlog: Async config notification
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER4 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER4
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER5 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER5
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER6 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER6
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER7 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER7
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER8 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER8
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER9 wmi connection failed: Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER9
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER10 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER10
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER11 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER11
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER12 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER12
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER13 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER13 
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER14 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER14
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER15 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER15
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER16 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER16
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER17 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER17
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER18 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER18
2007-09-07 15:32:26 WARNING zen.zeneventlog: SERVER19 wmi connection failed: 
Desc
2007-09-07 15:32:26 WARNING zen.zeneventlog: removing SERVER19






-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=10473#10473

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to