I have 64 bit data collection and graphs working, but with a side effect.

What I did:

- Copied ethernetCsmacd_64 from /Devices to a portion of the tree where I want 
to use it.
- Renamed it in that new location to ethernetCsmacd. I did this since the 
devices report themselves as the ethernetCsmacd type and couldn't get it to 
graph properly when leaving it as _64.

Results:
64 bit data collection via v2c works and graphs under each interface type also 
work using the new data.

Problem:
When I open up the 'Perf Tab', I now see two duplicate sets of 3 blank graphs 
(6 total). These graphs shouldn't even show up on the 'Perf Tab'. They are:

Thoughput, Packets, and Errors

I'm sure my method of getting ethernetCsmacd_64 to work caused this.

What's the proper way to get the 64 bit counters working for ethernet devices 
and avoid this side effect? 

Thanks




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=11862#11862

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to