Thanks, I applied the patch and restarted the whole zenoss (just to be sure). Now the ifOperStatus is "up". I'll wait to get some data and report back.

Is there a way to remodel a group of device at once ? I've got about 50 devicec to update...

I realize this reply is probably too late for your current purposes, but figured the answer could be useful to you and others in the future. You can do remodel entire device classes from the command line..

# Remodel all Windows devices
zenmodeler run --path=/Devices/Server/Windows

# Only collect interface information for Windows devices
zenmodeler run --path=/Devices/Server/Windows -- collect=snmp.InterfaceMap