On Mar 14, 2008, at 9:47 PM, Dennis B. Hopp wrote:
I upgraded to version 2.1.3 today. I originally had the error that is discussed here:

http://community.zenoss.com/forums/viewtopic.php?p=17233

And removing the pickle files fixed that, but now zenperfsnmp.log shows this error:

2008-03-14 20:28:29 WARNING zen.zenperfsnmp: Error reading value for "T1 0/3" on border.osteopathic.org (oid .1.3.6.1.2.1.2.2.1.11.7 is bad)

That is just some of them. Pretty much every switch I have (both nortel and cisco) and every router (all cisco) have this problem.

These errors were likely occurring before the upgrade, but not being reported. They aren't much to worry about. These interfaces types probably don't expose the if(In/Out)Errors and the other OIDs that are being complained about. I'd recommend creating new templates named the same thing as the interface "type" that these T1s are set to, and only collect values that are present on these types of interfaces.

The reason the default interface template in Zenoss is called ethernetCsmacd is because Zenoss will try to find a template for an interface based on its "type." If it can't find a template that matches, it will fall back to ethernetCsmacd.