On Mar 14, 2008, at 9:47 PM, Dennis B. Hopp wrote:
I upgraded to version 2.1.3 today. I originally had the error that
is discussed here:
http://community.zenoss.com/forums/viewtopic.php?p=17233
And removing the pickle files fixed that, but now zenperfsnmp.log
shows this error:
2008-03-14 20:28:29 WARNING zen.zenperfsnmp: Error reading value for
"T1 0/3" on border.osteopathic.org (oid .1.3.6.1.2.1.2.2.1.11.7 is
bad)
That is just some of them. Pretty much every switch I have (both
nortel and cisco) and every router (all cisco) have this problem.
These errors were likely occurring before the upgrade, but not being
reported. They aren't much to worry about. These interfaces types
probably don't expose the if(In/Out)Errors and the other OIDs that are
being complained about. I'd recommend creating new templates named the
same thing as the interface "type" that these T1s are set to, and only
collect values that are present on these types of interfaces.
The reason the default interface template in Zenoss is called
ethernetCsmacd is because Zenoss will try to find a template for an
interface based on its "type." If it can't find a template that
matches, it will fall back to ethernetCsmacd.