Alright!!! it looks like all the mibs are loaded with the related OID's

Here are the steps i took to accomplish this.

1) download all needed mibs from ftp://ftp-sj.cisco.com/pub/mibs/v2/
2) install below mibs in the order listed:
        SNMPv2-SMI.my

        SNMPv2-TC.my

        SNMPv2-MIB.my

        RFC1213-MIB.my

        IF-MIB.my

        CISCO-SMI.my

        CISCO-PRODUCTS-MIB.my
 
        RFC1155-SMI

        CISCO-TC.my 

****make sure all mibs load with OIDs listed****
When i loaded these mibs by themselves some didnt load correctly. I was able to 
get them all to load fully when i ran them all at once.

3) Load all other wanted mibs from the same site: 
ftp://ftp-sj.cisco.com/pub/mibs/v2/

Here are some suggested mibs for general monitoring

CISCO-CONFIG-MAN-MIB <-----MUST change all values inside the mib from 
"Unsigned64" to "Unsigend32" in order for it to load
CISCO-ENTITY-ALARM-MIB
CISCO-ENVMON-MIB
CISCO-PROCESS-MIB
CISCO-SYSLOG-MIB
HOST-RESOURCES-MIB
IANAifType-MIB
IEEE802dot11-MIB
OLD-CISCO-INTERFACES-MIB
OLD-CISCO-SYSTEM-MIB
OLD-CISCO-TCP-MIB
OLD-CISCO-TS-MIB
RFC-1212
RFC-1215
RFC1155-SMI
RFC1158-MIB
RFC1229-MIB

Hope this post help

HUGE thanks to Sartuche24, sabryan and Russ for all the help




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=18969#18969

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to