We've got Cisco 7206 as our core routers and zenmodeler can't properly model 
these devices. I have the template set to ethernetCsmacd_64. Perhaps there's 
just too much info reported via SNMP (routing tables?) and zenmodeler can't 
handle it. The modeler just times out. I can walk the device fine from the 
command line. A horrible side effect is that zenmodeler ends crashing zenhub.

2008-06-10 17:56:36 WARNING zen.ZenModeler: client inet1 timeout
2008-06-10 17:56:36 INFO zen.ZenModeler: scan time: 180.87 seconds

This is the ONLY device on a fresh install of zenoss 2.2.0 (source install). 
Zenmodeler bars and crashes zenhub.

 PID USER      PR  NI  VIRT  RES  SHR S %CPU %MEM    TIME+  COMMAND             
                     
  490 zenoss    25   0  501m 328m 3580 R  100  8.3   1:32.91 python             
                   

[EMAIL PROTECTED]:/usr/local/zenoss/log> ps -ef | grep zenhub
zenoss     490     1  0 17:43 ?        00:00:01 /usr/local/zenoss/bin/python 
/usr/local/zenoss/Products/ZenHub/zenhub.py --configfile 
/usr/local/zenoss/etc/zenhub.conf --cycle --daemon

If you guys need logs, I can forward them to you.




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=21195#21195