I've never come across that problem, you must have a lot of very small files.. 
[Wink] 

It appears that Net-SNMP has an oid of 1.3.6.1.4.1.2021.9.1.10 that measures 
inode usage. You could edit the device collector plugin and add that OID, or 
just create a new template for your device class, using that OID and a 
threshold.




-------------------- m2f --------------------

Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=21447#21447