using --debug outputs this.
ciscoV2]# zenmib run --debug CISCO-TC.my CISCO-SMI.my CISCO-CIDS-MIB.my
INFO:zen.zenmib:Skipping file
/opt/zenoss/share/mibs/irtf/IRTF-NMRG-SMING-EXTENSIONS
INFO:zen.zenmib:Skipping file /opt/zenoss/share/mibs/irtf/IRTF-NMRG-SMING
INFO:zen.zenmib:Skipping file /opt/zenoss/share/mibs/irtf/IRTF-NMRG-SMING-TYPES
INFO:zen.zenmib:Loaded mib CISCO-TC
INFO:zen.zenmib:Loaded mib CISCO-SMI
ERROR:zen.zenmib:Failed to load mib: CISCO-CIDS-MIB.my
ERROR:zen.zenmib:Error: CISCO-CIDS-MIB.my:30: the SPPI construct/keyword
`Unsigned64' may not be used in a MIB
Unsigned64 within the mib are
Unsigned64
FROM CISCO-TC
cidsGeneralEventId OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Identifies the sequence number of an event.
This value needs to be unique within the scope
of the originating host."
::= { cidsGeneral 1 }
cidsAlertSummaryInitialAlert OBJECT-TYPE
SYNTAX Unsigned64
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Serial number for the initial alert, which is
guaranteed unique within the scope of the
originating host."
::= { cidsAlert 11 }
does anyone know what will happen if these are changed or removed?
Thanks
-------------------- m2f --------------------
Read this topic online here:
http://community.zenoss.com/forums/viewtopic.php?p=22835#22835
-------------------- m2f --------------------
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users