jbaird wrote: > After upgrading to 2.2.3 from 2.2.0, ALL of our performance graphs for all > devices have gaps in their data as seen in this screenshot: > > http://shell.vaerchi.com/~corrupt/zen/zengap.jpg > > Does anyone know what could be causing this?
I think this is likely caused by the ping topology being built within zenhub in version 2.2. It used to be built within the zenping daemon. By default this ping topology is rebuilt every 20 minutes. You can control this by going into Collectors and changing the "Config Cycle Interval" Before you do this, I think we might have a solution to the problem that doesn't make you increase this setting. Try running the following as the zenoss user. zenpatch 9748 zenhub restart zenping restart -------------------- m2f -------------------- Read this topic online here: http://community.zenoss.com/forums/viewtopic.php?p=23461#23461 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users