On Sep 8, 2008, at 5:35 AM, oyvindha wrote:
The zenwin log is filled with this;

2008-09-07 23:54:39 ERROR watchdog: Child died: Killed with signal 11
2008-09-08 00:04:39 ERROR watchdog: Restarting zenwin
2008-09-08 00:04:44 WARNING zen.zenwin: Reconnected to ZenHub
2008-09-08 00:04:44 INFO zen.zenwin: Setting configCycleInterval to 120
2008-09-08 00:04:44 INFO zen.zenwin: Setting winCycleInterval to 900
2008-09-08 00:04:46 INFO zen.zenwin: Starting zenwin

It could be that zenwin isn't able to complete its cycle within the time allotted. Try going into Collectors -> localhost -> Edit and changing the Windows Service Cycle Interval to 120 seconds instead of 60. You'll likely want to do the same thing with the Event Log Cycle Interval too.