On Sep 8, 2008, at 5:35 AM, oyvindha wrote:
The zenwin log is filled with this;
2008-09-07 23:54:39 ERROR watchdog: Child died: Killed with signal 11
2008-09-08 00:04:39 ERROR watchdog: Restarting zenwin
2008-09-08 00:04:44 WARNING zen.zenwin: Reconnected to ZenHub
2008-09-08 00:04:44 INFO zen.zenwin: Setting configCycleInterval to
120
2008-09-08 00:04:44 INFO zen.zenwin: Setting winCycleInterval to 900
2008-09-08 00:04:46 INFO zen.zenwin: Starting zenwin
It could be that zenwin isn't able to complete its cycle within the
time allotted. Try going into Collectors -> localhost -> Edit and
changing the Windows Service Cycle Interval to 120 seconds instead of
60. You'll likely want to do the same thing with the Event Log Cycle
Interval too.
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users