Oddly, I renamed my Zenoss box from localhost to its actual hostname and have not seen these alerts since.
Clayton Taylor Dillard Network Security Enthusiast Aim for the truth - it works! James Pulver wrote: > I think it just means you're getting close to your cycle time to > complete pollings of WMI. So Zenoss either a) has too many windows > devices to poll via WMI for the cycle time or b) something is causing > some of your Windows devices to hang up and not respond for a while on > a WMI query occasionally. > -- > James Pulver > Information Technology Area Supervisor > LEPP Computer Group > Cornell University > > > > cdillardhsp wrote: >> I'm getting off and on zenwin cycle time errors. The error clears >> after a period of time, then reappears. >> >> threshold of zenwin cycle time exceeded: current value 122.32 >> >> Zenwin log says: >> 2008-09-06 21:46:27 INFO zen.zenwin: Async config notification >> 2008-09-06 21:48:35 ERROR watchdog: Timeout: getting status from process >> 2008-09-06 21:58:35 ERROR watchdog: Restarting zenwin >> 2008-09-06 21:58:37 WARNING zen.zenwin: Reconnected to ZenHub >> 2008-09-06 21:58:37 INFO zen.zenwin: Setting configCycleInterval to 360 >> 2008-09-06 21:58:38 INFO zen.zenwin: Starting zenwin >> >> Anybody have any ideas? >> >> >> >> >> -------------------- m2f -------------------- >> >> Read this topic online here: >> http://community.zenoss.com/forums/viewtopic.php?p=24761#24761 >> >> -------------------- m2f -------------------- >> >> >> >> _______________________________________________ >> zenoss-users mailing list >> [email protected] >> http://lists.zenoss.org/mailman/listinfo/zenoss-users > _______________________________________________ > zenoss-users mailing list > [email protected] > http://lists.zenoss.org/mailman/listinfo/zenoss-users _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users