On 10/21/08 8:49 AM, "david snt" <[EMAIL PROTECTED]> wrote:
> Can anyone help me out in monitoring CPU temperature of a CISCO 7206 series > routers and also the Traffic/Bandwidth on it Create your own... I'm unable to locate an OID for CPU temp but these should help out: Inlet and outlet string # snmpwalk -v2c -cxxxx my-7206 1.3.6.1.4.1.9.9.13.1.3.1.2 Inlet and outlet temperature # snmpwalk -v2c -cxxxx my-7206 1.3.6.1.4.1.9.9.13.1.3.1.3 Use existing templates as a guide and read the documentation on how to build your own templates and apply thresholds. Interface stats should already be available. Re, -- Chuck _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users