On Dec 31, 2008, at 1:22 PM, mshundal wrote:
> trying to get 95th percentile graphs going for some my interfaces;  
> searched in the forums and google but did not find anything useful  
> or current.
>
> anyone currently doing this? is so would you mind sharing?

This is quite easy to do. Go to the template that you're using to  
monitor the interfaces (likely /Devices/ethernetCsmacd) and edit the  
Throughput graph definition. Add the following on the custom tab.

VDEF:in95=ifInOctets,95,PERCENT
VDEF:out95=ifOutOctets,95,PERCENT
COMMENT:\s
COMMENT:95th %ile over current period\: \n
HRULE:in95#00ff00:95th % In
GPRINT:in95:= \t %0.2lf%Sbps \n
HRULE:out95#ff00ff:95th % Out
GPRINT:out95:= \t %0.2lf%Sbps