On Jan 14, 2009, at 10:39 AM, James Pulver wrote:
> I have some Cisco Aeronets that we're grabbing everything from. The
> upside is we don't miss anything, the downside is we get multiple  
> events
> for certain actions, like a radio reset. For reasons I'm not sure of,
> the Aeronet doesn't send multiple clears... (To clarify, I mean we get
> downs via SNMP, Syslog and traps, but only one of those is a clear  
> event).
>
> I'm not sure, but could I use something (event transform?
> EventClearClasses? something else?) to clear the multiple down notices
> with the single up notice?

Yes, one clear event can clear 0 or more events. Zenoss looks at the  
following fields.

device
component
eventKey (or summary if eventKey is blank)
eventClass (or zEventClearClasses of the eventClass if they exist)

Any active events that match these criteria will be moved to history  
along with the clear event.