I think your problem is you're using MYVALUE where you should be using
abc in the Zenoss UI / config.
Your Datapoint should be named abc
Your Graphpoint would be Access_to_server_abc ...
--
James Pulver
Information Technology Area Supervisor
LEPP Computer Group
Cornell University
psonenberk wrote, On 1/19/2009 9:12 AM:
> Hello all,
> I want to create a graph with some values (for example "Access_to_server").
> The values for graph returns a script, its configuration is below.
> Script returns right value but graph ("Access to server") is empty.
> It seems there is some problem between items, with theirs connection
> or declaration.
> Would somebody tell me there is configuration mistake?
> Thank you very much for your help.
> Have a nice day.
>
>
> There is script in the server and that script returns this string:
> MYVALUE OK|abc=23
> (Between "OK" and "abc" is "|". )
>
> Zenoss has these configurations:
> /Device/Server/Linux/beta/Templates/Number_of_access/Access_to_server
>
> Data Sources
> ------------
> Name Access_to_server
> Source Type COMMAND
> Enabled True
> Use SSH False
> Component Event CLass /cmd/OK
> Event key Server Access
> Security Warning
> Cycle Time 120
> Command Template /usr/local/zenoss/common/libexec/access.sh
>
> Test Against Device is OK!!!
>
> The script "access.sh" returns (last raw):
> /bin/echo "MYVALUE OK|abc="$num
> (Between "OK" and "abc" is "|". )
>
> [Owner of the "access.sh" is zenoss.zenoss]
>
> Data Points
> -----------
> Name MYVALUE
> Type GAUGE
> RRD Min 0
> RRD Max 50
> Create cmd
>
>
> Graph Points
> ------------
> Seq Name Type Description
> 0 MYVALUE DataPoint Access_to_server
>
> Name Number_of_access
> Height 100
> Width 500
> Units quantity
> Logarithmic Scale False
> Base 1024 False
> Min Y 0
> Max Y 50
> Has Summary True
>
>
> There are these items on the screen "Performance Template":
>
> Name Number_of_access
> Sescription Number of access to server
>
> Data Sources
> Name Source
> Access_to_server /usr/local/zenoss/common/libexec/access.sh
>
> Thresholds
>
> Graph Definitions
> Name Graph Points Units Height Width
> Access_to_server MYVALUE quantity 100 500
>
>
>
>
> -------------------- m2f --------------------
>
> Read this topic online here:
> http://forums.zenoss.com/viewtopic.php?p=30239#30239
>
> -------------------- m2f --------------------
>
>
>
> _______________________________________________
> zenoss-users mailing list
> [email protected]
> http://lists.zenoss.org/mailman/listinfo/zenoss-users
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users