On Apr 15, 2009, at 6:34 PM, laguest wrote:
> Agent: zenwin
> Zenoss:  2.2.3

It looks like there was a change in how we handled this nextEvent call  
between 2.2.3 and 2.2.4. We set a timeout on the operation in 2.2.4.  
The reason you get this error is that the watchdog found zenwin to be  
hung, and when zenwin restarted it reported that this was the function  
call during which the hang occurred.

You may want to consider upgrading to 2.2.4 to get the fix. It could  
be dangerous to zenpatch in because the changeset affects a lot of  
other code as well. The related ticket is linked below.

Ticket #2918: WinService down events do not repeat
http://dev.zenoss.org/trac/ticket/2918
_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to