I figured out the issue. One of the devices was using snmp v2c, the other v1. 
So the interfaces on the v2c device were being bound to ethernetCsmacd_64 and 
the interfaces on the v1 device were being bound to ethernetCsmacd.

So that's straightened out.

But I still can't get summary lines in my graphs for the 2 sets of data points. 

In the end I want one line for In, one line four out that are basically....
CDEF:InTotal:deviceA_ifHCInOctets_ifHCInOctets,deviceB_ifHCInOctets_ifHCInOctets,+
CDEF:OutTotal:deviceA_ifHCOutOctets_ifHCOutOctets,deviceB_ifHCOutOctets_ifHCOutOctets,+




-------------------- m2f --------------------

Read this topic online here:
http://forums.zenoss.com/viewtopic.php?p=34551#34551

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to