Hello,

I'm tinkering with Zenoss Core to eval it's use for my organization, and right 
now I'm trying to understand Zenoss' event handling and correlation. 
Right now I have a couple lab Cisco routers and switches in Zenoss, and these 
devices are sending SNMP traps and syslog to Zenoss. I've fed Zenoss all the 
appropriate MIBs, so trap translation is occurring properly. What does not seem 
to be working properly is figuring out which interface a linkup/down trap is 
for. When Zenoss gets a linkUp/Down trap from my switch, it properly translates 
all the values, but the Component is blank. My understanding is that the 
component field should show the interface that is affected for these types of 
events. This does work as expected for perf monitoring on my router interfaces. 
The only thing I can see that is unusual is that my switch device has no 
interfaces listed on its OS tab. The only thing I can see related to this is an 
error from zenmodeler:

2009-06-29 15:00:37 ERROR zen.ZenModeler: Unable to get data for 
lab-sw.noc.sonic.net from either ipAddrTable or ipNetToMediaTable -- skipping 
model

This is an L2 only switch, so it shouldn't have much in the way of IP 
information, but Zenoss should be able to walk IfDescr and the like to learn 
about interface names/utilization.
I'm hoping someone can help me figure out how to get snmp trap 
translation/correlation fully working.

Thanks in advance!




-------------------- m2f --------------------

Read this topic online here:
http://forums.zenoss.com/viewtopic.php?p=36485#36485

-------------------- m2f --------------------



_______________________________________________
zenoss-users mailing list
[email protected]
http://lists.zenoss.org/mailman/listinfo/zenoss-users

Reply via email to