Rodyan: Whats happening is Zenoss is testing oid .1.3.6.1.2.1.2.2.1.14.80.0 rather then oid .1.3.6.1.2.1.2.2.1.14.80. This is because interfaces are normally enumerated from oid .1.3.6.1.2.1.2.2.1.14 automatically. Are you manually adding OID's to monitor or have you added the device and modeled it's interfaces? If you've modeled the interfaces and need to monitor more parameters you can edit the interface template. This will allow Zenoss to enumerate the interfaces and collect each interfaces template based OIDs. To do this visit the device, then OS, then the interface in question, and finally click template. You may create local copies for special/testing cases or edit the main template.
-------------------- m2f -------------------- Read this topic online here: http://forums.zenoss.com/viewtopic.php?p=37029#37029 -------------------- m2f -------------------- _______________________________________________ zenoss-users mailing list [email protected] http://lists.zenoss.org/mailman/listinfo/zenoss-users