Hello Folke,
I think I have a solution...
before you install the netcom-MIB-file, edit it and change the following line:
Original:
Code:
IMPORTS
OBJECT-TYPE
FROM SNMPv2-SMI-v1 <--
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION
FROM SNMPv2-TC-v1 <--(delete "-v1")
;
Change to:
Code:
IMPORTS
OBJECT-TYPE
FROM SNMPv2-SMI <--(delete "-v1")
TRAP-TYPE
FROM RFC-1215
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION
FROM SNMPv2-TC <--(delete "-v1")
;
hope it helps
regards
dbuck