On 28 June 2011 17:47, Martin Sustrik <[email protected]> wrote: > This problem occurs if all the following conditions are true: > > * A single send call or WSASend call fills the whole underlying socket > send buffer. > > So, the problem would occur only if the default socket buffer would be less > than 8kB. Is that the case? > > I read it as less than or equal to, a 8KB send would fill the entire 8KB send buffer.
-- Steve-o
_______________________________________________ zeromq-dev mailing list [email protected] http://lists.zeromq.org/mailman/listinfo/zeromq-dev