Hi Pritesh, You're talking about the task ventilator?
The second send doesn't block. The task pipeline can be a little puzzling at first; best thing is to draw the design on paper and try to understand the message flow from piece to piece. -Pieter On Tue, Apr 9, 2013 at 9:56 AM, Pritesh Acharya <priteshacha...@gmail.com> wrote: > In the parallel pipe example, > > zmq_bind (sender, "tcp://*:5557"); > > zmq_connect (sink, "tcp://localhost:5558"); > > and s_send (sink, "0"); > > s_send (sender, string); > > how does the control continues in the first s_send and block on the second > s_send, when I haven't started sink on 5558 port. > > ? > > > _______________________________________________ > zeromq-dev mailing list > zeromq-dev@lists.zeromq.org > http://lists.zeromq.org/mailman/listinfo/zeromq-dev > _______________________________________________ zeromq-dev mailing list zeromq-dev@lists.zeromq.org http://lists.zeromq.org/mailman/listinfo/zeromq-dev