Hi all,

yesterday we had a drive failure on a fc-al jbod with 14 drives.
Suddenly the zpool using that jbod stopped to respond to I/O requests and we 
get tons of the following messages on /var/adm/messages:

Sep  3 15:20:10 fb2 scsi: [ID 107833 kern.warning] WARNING: /scsi_vhci/[EMAIL 
PROTECTED] (sd52):
Sep  3 15:20:10 fb2     SCSI transport failed: reason 'timeout': giving up

"cfgadm -al" or "devfsadm -C" didn't solve the problem.
After a reboot  ZFS recognized the drive as failed and all worked well.

Do we need to restart Solaris after a drive failure??

Gino
 
 
This message posted from opensolaris.org
_______________________________________________
zfs-discuss mailing list
zfs-discuss@opensolaris.org
http://mail.opensolaris.org/mailman/listinfo/zfs-discuss